{"product_id":"seaflo-sfat-100-125-01-accumulator-tank","title":"1.0 L Water System Accumulator Tank, SFAT-100-125-01 Pressure Buffer with 1\/2 Inch MNPT Ports for RVs and Boats","description":"\u003cdiv style=\"max-width:760px;line-height:1.7;overflow-wrap:anywhere;\"\u003e\n\u003ch2\u003eSmoother tap flow. Fewer pump starts.\u003c\/h2\u003e\n\u003cp\u003eThe \u003cstrong\u003eSEAFLO 1.0 L accumulator tank\u003c\/strong\u003e helps steady the pulsing water flow you can feel when a pressure-controlled pump repeatedly switches on and off. Model \u003cstrong\u003eSFAT-100-125-01\u003c\/strong\u003e adds an air cushion on the pump's discharge side for compatible RV and boat water systems.\u003c\/p\u003e\n\u003cp style=\"border-left:3px solid #183b56;padding:12px 16px;margin:20px 0;background:#f4f7f9;\"\u003e\u003cstrong\u003e1.0 L nominal volume · 1\/2-inch MNPT ports · No electrical connection\u003c\/strong\u003e\u003cbr\u003eThis is an accumulator tank for a water system. It is supplied as a separate component, not a complete pump system.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"#sfat-selection\"\u003eChoose a capacity\u003c\/a\u003e · \u003ca href=\"#sfat-specifications\"\u003eSpecifications\u003c\/a\u003e · \u003ca href=\"#sfat-installation\"\u003eInstallation\u003c\/a\u003e · \u003ca href=\"#sfat-faq\"\u003eQuestions \u0026amp; answers\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003eWhat changes at the tap?\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMore even flow at low demand:\u003c\/strong\u003e the air cushion absorbs pressure fluctuations as the pump cycles, particularly when a tap is only partly open.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLess repeated switching:\u003c\/strong\u003e stored pressurised water can supply small demands between pump starts in a correctly selected and adjusted system.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eA quieter water system:\u003c\/strong\u003e cushioning pressure changes can help reduce the disturbance associated with repeated cycling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNo extra wiring:\u003c\/strong\u003e the tank works through compressed air and water pressure; it has no motor or electrical supply connection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHow the accumulator works\u003c\/h3\u003e\n\u003cp\u003eWhen the pump runs, water enters the tank and compresses the air cushion. When a tap opens, the air cushion pushes stored water back into the system as pressure falls. The pump restarts when its own cut-in pressure is reached. This buffers the pressure change between the pump and the outlets.\u003c\/p\u003e\n\u003cp\u003eFewer pump cycles can mean fewer pressure-switch operations. The tank does not repair a failed switch or guarantee that a switch will never fail.\u003c\/p\u003e\n\u003ch3 style=\"scroll-margin-top:220px;\" id=\"sfat-selection\"\u003eChoose between 0.75 L and 1.0 L\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e0.75 L — SFAT-075-125-01:\u003c\/strong\u003e the lower nominal-volume option in this pair.\u003cbr\u003e\u003ca style=\"display:inline-block;min-height:44px;padding:8px 0;box-sizing:border-box;\" href=\"\/de\/products\/seaflo-sfat-075-125-01-accumulator-tank\"\u003eView the 0.75 L model\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1.0 L — SFAT-100-125-01:\u003c\/strong\u003e the higher nominal-volume option.\u003cbr\u003e\u003ca style=\"display:inline-block;min-height:44px;padding:8px 0;box-sizing:border-box;\" href=\"\/de\/products\/seaflo-sfat-100-125-01-accumulator-tank\"\u003eYou are viewing the 1.0 L model\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eBoth models share the connection size and maximum operating pressure shown below. Choose after checking your pump controls and the actual space available. A larger nominal tank volume alone does not establish the right fit for a particular installation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal volume is not usable water draw-off.\u003c\/strong\u003e Air and water share the tank volume. The amount of water delivered before the pump restarts depends on air pre-charge and the pump's cut-in and cut-out pressures.\u003c\/p\u003e\n\u003ch3 style=\"scroll-margin-top:220px;\" id=\"sfat-specifications\"\u003eSFAT-100-125-01 specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBrand:\u003c\/strong\u003e SEAFLO\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel:\u003c\/strong\u003e SFAT-100-125-01\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNominal internal volume:\u003c\/strong\u003e 1.0 L\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInlet \/ outlet:\u003c\/strong\u003e 1\/2-inch MNPT male threads\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaximum tank operating pressure:\u003c\/strong\u003e 125 PSI \/ 8.6 bar\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFactory air pre-charge:\u003c\/strong\u003e 10 PSI \/ 0.7 bar; adjust for the actual pump system before use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir fill valve:\u003c\/strong\u003e standard automotive-style tyre valve\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstallation position:\u003c\/strong\u003e downstream of the pump, on the discharge side\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe maximum pressure is the tank limit, not a recommended pump setting. Check the pressure rating of every component in the system.\u003c\/p\u003e\n\u003ch3\u003eCheck these points before ordering\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePump control:\u003c\/strong\u003e confirm that an accumulator is suitable for the actual pump and its control arrangement. Follow the pump manufacturer's instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThread standard:\u003c\/strong\u003e match 1\/2-inch MNPT male ports with suitable mating fittings. A nominal 1\/2-inch connection alone does not prove compatibility with another thread standard.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSpace and support:\u003c\/strong\u003e confirm the actual unit's mounting and clearance requirements, allowing access to the air valve and water connections.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSystem condition:\u003c\/strong\u003e diagnose leaks, restrictions or pump faults before treating an accumulator as the solution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 style=\"scroll-margin-top:220px;\" id=\"sfat-installation\"\u003eInstallation and pre-charge setup\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolate and depressurise.\u003c\/strong\u003e Switch off the pump's power supply and open a tap to safely release water pressure before installation or checking air pre-charge.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the pump's cut-in pressure.\u003c\/strong\u003e The SEAFLO tank manual specifies pre-charge \u003cstrong\u003e3 PSI \/ 0.2 bar below the pump's cut-in pressure\u003c\/strong\u003e. Cut-in means the pressure at which the pump starts. The factory 10 PSI charge is not a universal final setting.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInstall on the discharge side.\u003c\/strong\u003e Secure the tank and pipework with matching connections, following the tank manual and the actual pump's instructions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCommission and recheck.\u003c\/strong\u003e Restore the water supply and pump power, purge air through an outlet, then check for leaks and correct pump operation. Check pre-charge periodically with the pump off and water pressure released.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003cp style=\"border-left:3px solid #183b56;padding:12px 16px;margin:20px 0;background:#f4f7f9;\"\u003e\u003cstrong\u003eUse within the stated pressure limit.\u003c\/strong\u003e Do not over-pressurise the tank. Follow the manufacturer manual for installation and maintenance; do not use this water-system tank for petrol, gasoline or other flammable fluids.\u003c\/p\u003e\n\u003ch3\u003eWhen pulsing needs a different repair\u003c\/h3\u003e\n\u003cp\u003eIf the pump cycles with all taps closed, fails to build pressure or continues running unexpectedly, investigate the system rather than relying on an accumulator to mask the symptom. Leaks, trapped air, blocked strainers, plumbing restrictions and faulty pump controls may require separate attention. Stop the pump and follow its own troubleshooting instructions where appropriate.\u003c\/p\u003e\n\u003ch3 style=\"scroll-margin-top:220px;\" id=\"sfat-faq\"\u003eQuestions \u0026amp; answers\u003c\/h3\u003e\n\u003ch4\u003eWill it help with water that alternates between strong and weak flow?\u003c\/h4\u003e\n\u003cp\u003eIt can help when the variation comes from a pressure-controlled pump repeatedly starting and stopping. It cannot establish the cause of every flow problem; check the pump and plumbing if symptoms remain.\u003c\/p\u003e\n\u003ch4\u003eCan it prevent the pressure switch from burning out?\u003c\/h4\u003e\n\u003cp\u003eReducing repeated pump starts can reduce the number of switch operations, but there is no guarantee against switch failure. An already damaged switch needs diagnosis and repair or replacement.\u003c\/p\u003e\n\u003ch4\u003eDoes the 1.0 L model release 1.0 L before the pump restarts?\u003c\/h4\u003e\n\u003cp\u003eNo. 1.0 L is nominal internal volume. Actual draw-off depends on the air charge and the pump's pressure settings.\u003c\/p\u003e\n\u003ch4\u003eIs it a 12 V or 24 V part?\u003c\/h4\u003e\n\u003cp\u003eThe tank itself has no electrical connection. The separate pump must still have the correct voltage, wiring and protection for its installation.\u003c\/p\u003e\n\u003ch4\u003eCan I use the factory pre-charge without checking it?\u003c\/h4\u003e\n\u003cp\u003eCheck it against the actual pump's cut-in pressure. The tank manual calls for adjustment before use; do not use the pump's cut-out pressure as the reference.\u003c\/p\u003e\n\u003ch4\u003eAre adapters, hoses and a pump included?\u003c\/h4\u003e\n\u003cp\u003eThis listing covers the accumulator tank. If your installation needs adapters, hoses or a pump, confirm the required parts and package contents with ROQIFY before ordering.\u003c\/p\u003e\n\u003ch3\u003eManual and installation support\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/www.seaflomarinerv.com\/uploads\/soft\/20250613\/1-250613110Z64N.pdf\" target=\"_blank\" rel=\"noopener\"\u003eDownload the SEAFLO 0.75 \/ 1.0 L accumulator installation manual (PDF)\u003c\/a\u003e.\u003c\/p\u003e\n\u003cp\u003eFor help choosing a tank, send your pump model, cut-in \/ cut-out pressures, connection details and a photo of the available space. \u003ca href=\"\/de\/pages\/contact\"\u003eContact ROQIFY\u003c\/a\u003e or email \u003ca href=\"mailto:kitty@roqify.store\"\u003ekitty@roqify.store\u003c\/a\u003e. Trade buyers can include the required model and quantity.\u003c\/p\u003e\n\u003c\/div\u003e","brand":"SEAFLO","offers":[{"title":"Default Title","offer_id":71930162643197,"sku":"SFAT-100-125-01","price":34.9,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0807\/1751\/2957\/files\/1-2212231122455H.png?v=1794704527","url":"https:\/\/www.roqify.store\/de\/products\/seaflo-sfat-100-125-01-accumulator-tank","provider":"Roqify","version":"1.0","type":"link"}