Zu Inhalt springen
Free Shipping on Selected RV & Marine Accessories — Availability Shown at Checkout
Free shipping on selected parts — rates at checkout

1.0 L Water System Accumulator Tank, SFAT-100-125-01 Pressure Buffer with 1/2 Inch MNPT Ports for RVs and Boats

Ursprünglicher Preis $34.90 - Ursprünglicher Preis $34.90
Ursprünglicher Preis
$34.90
$34.90 - $34.90
Aktueller Preis $34.90
Verfügbarkeit:
100 auf Lager, bereit zum Versand

Shipping to Vereinigte Arabische Emirate · USD

Shipping options and final rates are shown at checkout.

See shipping information
Request a bulk quote

Produkt 1.0 L Water System Accumulator Tank, SFAT-100-125-01 Pressure Buffer with 1/2 Inch MNPT Ports for RVs and Boats

SKU SFAT-100-125-01

Part details at a glance

Fitment not yet confirmed
ROQIFY SKU SFAT-100-125-01

30-Day Return Policy

You have 30 days after receiving your item to request a return. Return shipping costs are the customer’s responsibility unless the item is damaged, defective, or incorrect.

Smoother tap flow. Fewer pump starts.

The SEAFLO 1.0 L accumulator tank helps steady the pulsing water flow you can feel when a pressure-controlled pump repeatedly switches on and off. Model SFAT-100-125-01 adds an air cushion on the pump's discharge side for compatible RV and boat water systems.

1.0 L nominal volume · 1/2-inch MNPT ports · No electrical connection
This is an accumulator tank for a water system. It is supplied as a separate component, not a complete pump system.

Choose a capacity · Specifications · Installation · Questions & answers

What changes at the tap?

  • More even flow at low demand: the air cushion absorbs pressure fluctuations as the pump cycles, particularly when a tap is only partly open.
  • Less repeated switching: stored pressurised water can supply small demands between pump starts in a correctly selected and adjusted system.
  • A quieter water system: cushioning pressure changes can help reduce the disturbance associated with repeated cycling.
  • No extra wiring: the tank works through compressed air and water pressure; it has no motor or electrical supply connection.

How the accumulator works

When the pump runs, water enters the tank and compresses the air cushion. When a tap opens, the air cushion pushes stored water back into the system as pressure falls. The pump restarts when its own cut-in pressure is reached. This buffers the pressure change between the pump and the outlets.

Fewer pump cycles can mean fewer pressure-switch operations. The tank does not repair a failed switch or guarantee that a switch will never fail.

Choose between 0.75 L and 1.0 L

0.75 L — SFAT-075-125-01: the lower nominal-volume option in this pair.
View the 0.75 L model.

1.0 L — SFAT-100-125-01: the higher nominal-volume option.
You are viewing the 1.0 L model.

Both models share the connection size and maximum operating pressure shown below. Choose after checking your pump controls and the actual space available. A larger nominal tank volume alone does not establish the right fit for a particular installation.

Nominal volume is not usable water draw-off. Air and water share the tank volume. The amount of water delivered before the pump restarts depends on air pre-charge and the pump's cut-in and cut-out pressures.

SFAT-100-125-01 specifications

  • Brand: SEAFLO
  • Model: SFAT-100-125-01
  • Nominal internal volume: 1.0 L
  • Inlet / outlet: 1/2-inch MNPT male threads
  • Maximum tank operating pressure: 125 PSI / 8.6 bar
  • Factory air pre-charge: 10 PSI / 0.7 bar; adjust for the actual pump system before use
  • Air fill valve: standard automotive-style tyre valve
  • Installation position: downstream of the pump, on the discharge side

The maximum pressure is the tank limit, not a recommended pump setting. Check the pressure rating of every component in the system.

Check these points before ordering

  • Pump control: confirm that an accumulator is suitable for the actual pump and its control arrangement. Follow the pump manufacturer's instructions.
  • Thread standard: match 1/2-inch MNPT male ports with suitable mating fittings. A nominal 1/2-inch connection alone does not prove compatibility with another thread standard.
  • Space and support: confirm the actual unit's mounting and clearance requirements, allowing access to the air valve and water connections.
  • System condition: diagnose leaks, restrictions or pump faults before treating an accumulator as the solution.

Installation and pre-charge setup

  1. Isolate and depressurise. Switch off the pump's power supply and open a tap to safely release water pressure before installation or checking air pre-charge.
  2. Check the pump's cut-in pressure. The SEAFLO tank manual specifies pre-charge 3 PSI / 0.2 bar below the pump's cut-in pressure. Cut-in means the pressure at which the pump starts. The factory 10 PSI charge is not a universal final setting.
  3. Install on the discharge side. Secure the tank and pipework with matching connections, following the tank manual and the actual pump's instructions.
  4. Commission and recheck. Restore the water supply and pump power, purge air through an outlet, then check for leaks and correct pump operation. Check pre-charge periodically with the pump off and water pressure released.

Use within the stated pressure limit. Do not over-pressurise the tank. Follow the manufacturer manual for installation and maintenance; do not use this water-system tank for petrol, gasoline or other flammable fluids.

When pulsing needs a different repair

If the pump cycles with all taps closed, fails to build pressure or continues running unexpectedly, investigate the system rather than relying on an accumulator to mask the symptom. Leaks, trapped air, blocked strainers, plumbing restrictions and faulty pump controls may require separate attention. Stop the pump and follow its own troubleshooting instructions where appropriate.

Questions & answers

Will it help with water that alternates between strong and weak flow?

It can help when the variation comes from a pressure-controlled pump repeatedly starting and stopping. It cannot establish the cause of every flow problem; check the pump and plumbing if symptoms remain.

Can it prevent the pressure switch from burning out?

Reducing repeated pump starts can reduce the number of switch operations, but there is no guarantee against switch failure. An already damaged switch needs diagnosis and repair or replacement.

Does the 1.0 L model release 1.0 L before the pump restarts?

No. 1.0 L is nominal internal volume. Actual draw-off depends on the air charge and the pump's pressure settings.

Is it a 12 V or 24 V part?

The tank itself has no electrical connection. The separate pump must still have the correct voltage, wiring and protection for its installation.

Can I use the factory pre-charge without checking it?

Check it against the actual pump's cut-in pressure. The tank manual calls for adjustment before use; do not use the pump's cut-out pressure as the reference.

Are adapters, hoses and a pump included?

This listing covers the accumulator tank. If your installation needs adapters, hoses or a pump, confirm the required parts and package contents with ROQIFY before ordering.

Manual and installation support

Download the SEAFLO 0.75 / 1.0 L accumulator installation manual (PDF).

For help choosing a tank, send your pump model, cut-in / cut-out pressures, connection details and a photo of the available space. Contact ROQIFY or email kitty@roqify.store. Trade buyers can include the required model and quantity.

Product details
Specifications & installation
Shipping Information

Availability and rates shown at checkout.

Here to Help

Get in touch with us Monday–Friday

RV & Marine Parts

Parts for maintenance, replacement and upgrades.

AFTER-SALES SUPPORT

Professional service you can rely on